Facts & Figures

pixel

Here's an overview of the most important facts about the Staudinger power plant.

Staudinger Hard Coal-Fired Power Plant
  Block 1 or 2 Block 3 
Net Electrical Output 249 MW each 293 MW
Commissioning 1965 1970
Firing hard coal hard coal
Steam Generators    
Steam Output 2 x 416 t/h 1.100 t/h
No. of Pulverized Coal or
Oil Burners
1 x 12 20
Fresh Steam Pressure/
Temperature
235 bar/540°C 187 bar/525°C
Fuel Consumption at Full Load 90 t/h 110 t/h
Generator    
Output 350 MVA 395 MVA
Voltage 21 kV 21 kV
Flue Gas Purification    
Nitrogen Removal 1st primary measures
2nd SCR
1st primary measures
2nd SCR
Dust Removal electrostatic filter electrostatic filter
Sulfur Removal - System Limestone-Based Wet
Scrubbing
Limestone-Based Wet
Scrubbing
Sulfur Removal - End Product Gypsum Gypsum
Flue Height 195 m 195 m
MW: megawatts
t/h: tons per hour
  MVA: megavolt amps
kV: kilo volts
 
Staudinger Hard Coal-Fired Power Plant
  Block 4 Block 5 
Net Electrical Output 622 MW 510 MW
Commissioning 1977 1992
Firing natural gas / fuel oil hard coal
Steam Generator    
Steam Output 2.000 t/h 1.500 t/h
No. of Pulverized Coal or
Oil Burners
16 16
Live Steam Pressure/
Temperature
191 bar/535°C 262 bar/545°C
Fuel Consumption at
Full Load
160.000 m³/h natural gas
or 135 t/h fuel oil
150 t/h
Generator    
Output 780 MVA 687 MVA
Voltage 21 kV 21 kV
Flue Gas Purification    
Nitrogen Removal primary measures 1st primary measures
2nd SCR
Dust Removal   electrostatic filter
Sulfur Removal - System   Limestone-Based Wet
Scrubbing
Sulfur Removal- End Product Gypsum  Gypsum
Flue Height 250 m Transmittal via
Cooling Tower
141.4 m
MW: megawatts
t/h: tons per hour
  MVA: megavolt amps
kV: kilo volts
© E.ON Kraftwerke GmbH 2010